8. Press the Reset key and follow the instructions on the screen and the unit will clear itself automatically. Because JB Tools is an independent re-seller, JB Tools is able to offer the products it sells at the most competitive prices, resulting in substantial cost-savings passed directly to JB Tools customers. Remove thumbscrews located under the vacuum pump shelf. When the display reads SUPPLY TANK EMPTY disconnect blue hose. The choices are: pounds/ounces, pounds, ounces, and kilograms. Semi Automatic simple to use Recovery, Recycle, Evacuate and Recharge machine. The information can significantly help you manage your automobile A/C repair business. 16 cubic inch drier w/ moisture indicator, .7 micron oilseparator, Ball Type Valves to control HI, LO, Recover, andVacuum, 1" Heavy duty tubular frame construction with 10" pneumatic wheels, 4.5" swivelcasters, R134a, R12, R22, R502, R404a, R402a, R401a, R 407c,R409a. Hoses and 5 CFM Vacuum Pump, Certified to SAE J3030 (37840 includes SAE J2788 and 37860 includes SAEJ2843). Timer will count down to display the time left. 6. With the systems Windows-based control tablet, we can remotely access your machine and provide training to show you how to use the machine and navigate the screens. All hoses may contain liquid refrigerant under pressure. When display reads INPUT SERIAL NUMBER enter serial number using the key pad. The unit will automatically shut off when the INLET pressure drops below 10 hg vacuum. Filter Change Procedure before Scheduled Filter Change. Wear proper personal protective equipment such as safety goggles and gloves. Ganhe 10 pontos por cada documento compartilhado e mais pontos a cada novo download recebido, Obtenha Pontos de Download para cada documento compartilhado, Ajude outros alunos e ganhe 10 pontos para cada resposta dada, Obtenha pontos premium para baixar documentos compartilhados e documentos Store sem esperar, Mtodo de Estudo Definitivo E-book Docsity, Guia Eficaz para Esquemas e Mapas Mentais, O guia para melhorar a sua autoconfiana, Manuais, Projetos, Pesquisas de Psicologia, Pea ajuda comunidade e tire suas dvidas relacionadas ao estudo, Descubra as melhores universidades em seu pas de acordo com os usurios da Docsity, Centro Universitrio do Leste de Minas Gerais (UNILESTEMG). If the refrigerant does not pass the identification process (98% purity) the unit will display the error message CONTAMINATED and the screen will show the results of the identification. 1/2 hp oil-filled hermetic compressor for speed and reliability. The LCD will read CONNECT HOSES PRESS ENTER TO CONTINUE 5. This mode is most often used after completing a repair that required opening the A/C system to the atmosphere. Press the START button. 19153) to the R-134a virgin cylinder. MODE 4 - Full Cycle, performs a complete recov- ery, recycling, evacuating and charging of an automobile A/C system. JB Tools Customer Satisfaction Guarantee: Although JB tools is often not an authorized re-seller of all the products it sells and is often not affiliated with the manufacturers or brands of the products it sells, JB Tools stands behind all of the products it sells, because the products JB Tools sells are genuine and authentic. The Recovery Only mode should be used to fully recovery and recycle all refrigerant from an air conditioning system. MODE 3 - Charge Only, adds refrigerant to an A/C system and is most commonly used to top off the system. RECOVERING CONTAMINATED REFRIGERANT WILL VOID ALL WARRANTIES AND MY CAUSE DAMAGE TO OTHER AUTOMOBILES THAT YOU SERVICE IN THE FUTURE. If yes is selected the unit will begin the refrigerant identification process. When adding R-134a to the tank of either a 37880, you will need to use the tank refill adapter sup- plied in the accessory kit. Connect the high and low side auto service hoses to the respective high and low side service ports on the automobile A/C system. 11 Mode 7 Refrigerant Management System The Refrigerant Management System built into the 37880 tracks all aspects of refrigeration usage. Ensure the automobile A/C system is turned off prior to selecting a mode on the ma- chine. WARNING: DO NOT OVER- TIGHTEN THE TANK REFILL ADAPTER. The current purge status is displayed in the upper right corner of the LCD when in Select Mode. Time (MINS) - Shows the time set for Vacuum. WARNING: DO NOT RECOVER CONTAMINATED REFRIGERANT WITH THIS UNIT. Over-lled recovery cylinders can explode causing severe injury and property damage. Press START to begin recovery operations. Real-time remote support, including set-up/start-up assistance. Repeat the identification process to insure the proper identification of the refrigerant purity level. If the RECOVERY HOLD option is not selected the unit will shut off at the required level of vacuum and the opera- tor must insure that the EPA standard (SAE J2211) is met. Refrigerant will transfer to the storage tank. Verify the automobile air conditioning system is off. We recommend pulling a vacuum for a minimum of 15 minutes to ensure that the system is evacuated. Mode Selection Keys The Mode Selection Keys allow the technician to select a specific operation. When the LCD reads SET VACUUM TIME, set the vacuum time by pressing and holding IN- CREASE or DECREASE until the desired time is shown. Contact with refrigerants may cause frostbite or other related injuries. Replace worn or damaged compo- nents. The unit will only purge when it is first turned on. Many items shown in our price list are custom-fabricated to customers order. Release the button and press ENTER to accept the vacuum time shown on the LCD. Outside Sales
The new J2788 standard requires that the unit lock out if the filter drier is not replaced at the proper interval. 12 Purging Non-Condensable Gases The 37880 is designed to automatically purge non- condesable gases such as air present in the storage tank.
5. Always inspect hoses, o-rings, and fittings for damage be- fore using equipment. Simple operation for oil waste and airpurge, Micro processor controlled recharge makes the AR2700 accurate to 1/10 oz or 4grams, Easy to read high and low pressuregauges, High efficiency 6 CFM vacuum pump will dehydrate the system to 50microns. LIT, YELLOW JACKET Electric/Manual Lightweight Flaring Tool Instructions Flaring Instructions Step 1: Use a reamer to clean the tube.. 9. Press the ENTER key. Step 1: FILL VACUUM PUMP WITH OIL 1. 6. Refrigerant measurement during charging is extremely accurate. The purge time is set to 30 seconds to minimize refrigerant loss. Replace the refrigerant identifier filter and continue using the refrigerant identi- fier. 239-529-0011. Manual de operao de estao de recuperao de sistema de ar condicionado. 5. Tire suas dvidas lendo as respostas dadas por outros alunos como voc. The unit will purge the next time it is turned off and on. 10 Models with the optional refrigerant identifier 37881 The unit will display IDENTIFY REFRIG ? To make your selection use the increase and decrease keys to toggle from Y to N. Press the Enter key to make your selection and then press the Start key to start the process. Yellow Jacket 37840 Refrigerant Management System Automatic for R-134a with 10? You must understand the proce- dures outlined in this manual. SAE J2843 for R-1234yf requires 98%+ purity for vehicle refrigerant in order to service the vehicle with any RR&R equipment. FUNCTION C - WEIGHT CONVERSION. Refer to Pre-Operation Check List. Not ready for R-1234yf? Minimum restocking charge 20% on standard items of current date coding and manufacture. MODE 2 Operational Steps 1. All refrigerant must be removed from the old filters before they are removed. Your email address will not be published. Follow this procedure to add refrigerant to the storage tank. Moisture in an A/C system can cause erratic operation and must be removed be- fore recharging the system with refrigerant. Open the service hose valves. FUNCTION B - DECREASE. By purchasing this product from JB Tools, purchasers may not be guaranteed any manufacturer-provided services offered by the manufacturer of this product (including any training or technical support that may otherwise be available). Bypass vacuum time by setting time to zero (FULL CYCLE MODE only). Dispose of recovered oil in a proper manner. Attach the tank refill adapter (Part No. Refer to the Pre-Operation Check List. LP SWITCH OPENED DURRING VAC- UUM HOLD REPEAT VACUUM CYCLE ERROR 14 LEAK CHECK FAILD FAILED TO HOLD VACUUM AFTER 5 ATTEMPTS REPEAT RECOVERY PROCESS CHECK FOR LEAKS ERROR 15 SYSTEM MAL- EEP-ROM Data read/write error REPLACE MICROPROCESSOR 16 37880 Repair Parts List Part # Description 95423 High Pressure Switch 95180 Vacuum Switch W/COMP Capacitor W/COMP Relay 38026 Differential Switch 38111 Membrane Touch Pad Microprocessor 95157 Circuit Breaker, 15 Amp 68826 Automatic Scale Assembly Part # Description 27296 R-134a Auto Low Side Blue Hose (10ft) 27696 R-134a Auto High Side Red Hose (10ft) 00849 R-134a Tank Vapor Blue Hose (30in) 00853 R-134a Tank Liquid Red Hose (30in) 19153 R-134a Tank Refill Adapter 95006 50lb Refrigerant Tank 38003 Filter-Dryer (1 per unit) 38019 Oil Bottle 38053 Service Compressor Ritchie Engineering Co., Inc. Recovery Division 6701 W. 110th St. Bloomington, MN 55438 USA Phone: 952-943-1333 Toll Free: 800-769-8370 Fax: 952-943-1605 Toll Free: 800-322-8684 E-mail: custserv@yellowjacket.com Web Site: www.yellowjacket.com Warranty Information LIMITED WARRANTY Ritchie Engineering guarantees YELLOW JACKET products to be free of defective material and workmanship which would affect the life of the product under normal use for the purpose for which it was designed. 3. 2.
Shop Specialty Tools with everyday low prices and fast shipping. Tablet follows manufacturers warranty. See recommended hose safety inspection procedure. Failure to replace the filter will cause damage to the refrigerant identifier and void all warranties related to the refrigerant identifier. Mode 5 Oil Inject When prompted, press this key and watch the oil inject bottle until the correct amount of oil has been injected. Press WEIGHT CONVERSION to change the displayed units of weight. The filters must be changed periodically to ensure the system is working properly.
50 pound storage tank (3784x) and 30 pound storage tank (3786x). Pesquise entre todos os recursos de estudo, Estude com provas passadas, TCCs e dicas teis. Models with the optional refrigerant identifier 37881 The unit will display IDENTIFY REFRIG ? To make your selection use the increase and decrease keys to toggle from Y to N. Press the Enter key to make your selection and then press the Start key to start the proc- ess.
Operation Keys START- Press START to begin a selected operational mode. items. All prices are in USD 2022 JB Tools Inc. Genius Ecommerce by 1Digital. The free downloadable app wirelessly calculates and displays the A/C systems actual pressures in an easy-to-read color format on the RMS tablet, as well as iOS or Android devices. After the system turns off, the unit will beep to alert the technician the job is complete. Manufacturers occasionally suggest that products be advertised at their suggested retail price. The filter driers are marked with a unique code that will be required to unlock the unit. The screens contain the following information: Screen 1: Last Job Information Run Time Refrigerant Recovered Refrigerant Charged Refrigerant Added Screen 2: Year-to-date Information Total Run Time Total Amount Recovered Total Amount Charged Refrigerant Added New WARNING: DO NOT RECOVER CONTAMINATED REFRIGERANT WITH THIS UNIT. Optional side bag with eight (8) pockets holds full sized notepad, two beverages, cell phone and more. However, JB Tools customers can rest assured that JB Tools stands behind its Warranty Program and its Manufacturer Matching Policy,100% of the time. Avoid cross-contamination of refrigerant. Special production items will have a higher restocking charge. Repeat the identification process to insure the proper identification of the refrigerant purity level. 1. 3. Estude fcil! The RESET may have to be pushed more than once to return to Select Mode screen. If this occurs take the appropriate steps to locate the leak and properly repair it. NON-WARRANTY RETURNS - Prior authorization must be obtained from home office for non-warranty returns. Uses of the refrigerant data include: Improved record keeping Accurate determination of net profits Reduced billing errors Minimized refrigerant loss from leaks and theft Reduced operator errors The refrigerant management information is stored in eight registers. Plug unit into a grounded 110V outlet. JB Tools commitment to 100% customer satisfaction is unparalleled, which is why JB Tools offers its customers a best-in-class Warranty Program to all of its customers on all products sold by JB Tools. Built for the workingman. Comes with a 50Lbs tank included with the purchase of an AR2700, 115 Volts, 50/60 HZ, Single phase, PSI/KPa gauges. When the unit stops, turn the selector knob to CLOSE, secure the system and unplug the machine. RESET- Press RESET to cancel the current opera- tion. If the refrigerant does not pass the identification proc- ess (98% purity) the unit will display the error message CONTAMINATED and the screen will show the results of the identification. Replace the refrigerant identifier filter and continue using the refrigerant identi- fier. Using a funnel, insert oil to the oil level line using the provided YELLOW JACKET vacuum pump oil. During the recovery operation, refrigerant is removed from both the high and low side of the automobile air condition- ing system. Release the button and press EN- TER to accept the vacuum hold time shown on the LCD. Shop Battery & Charging Systems with everyday low prices and fast shipping. Purchase the 37840 for R-134a today and we can update it to R-1234yf later with our optional (one time use) conversion kit. Press the RESET button. Utilizes manual ball valves in place of solenoids making the AR2700 impervious to contamination andsealants. If the unit fails the second time follow the on screen in- structions and take the appropriate steps to remove the contaminated refrigerant with a separate unit for re- moval of contaminated refrigerant. Press the RESET key to return to the SELECT MODE status. Make certain all safety devices are functioning properly before operating equipment. 5 Mode keys are located on the left side of the control panel. Turn on the main power switch. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OF QUALITY, WHETHER WRITTEN, ORAL OR IMPLIED. The easy-to-use, portable, full color interface walks you quickly through each step for easy operation and fast service. If the unit continues to display Y or an E and the tank pressure is near the value in the table below, contact Ritchie Engineering Customer Service at (800)769-8370. This mode also allows the tech- nician to verify the A/C system will hold a vacuum for a certain length of time. Shop Paint, Body & Exterior with everyday low prices and fast shipping. When the LCD reads SET VACUUM HOLD TIME, set the vacuum hold time by pressing and holding INCREASE or DECREASE until the desired time is shown. 1. MODE 1 Operational Steps 1. 7. Shop Apparel with everyday low prices and fast shipping.
Meets standard requirements for vacuum pull control and system leak test. Maintenance Reminders Approximate Pressure (psig) Temp (F) R-12 R-134a 65 74 74 70 80 81 75 87 88 80 96 97 85 102 115 Temp (F) R-12 R-134a 90 110 120 95 118 126 100 127 135 105 136 145 110 146 155 FILTER - MAINT-FILTER CHG DUE The 37880 has a unique filter system which ensures the refrigerant transferred to the storage cylinder is clean and moisture-free. Choose from high- or low-side charging for vehicles with only one service fitting. Mode 1 Recovery Only 7 6. Correction in the manner provided above shall constitute a fulfillment of all liabilities with respect to the quality, material and workman- ship of the product. Holding the button depressed will increase the rate of change. Discard used lubricant per applicable federal, state and local requirements. Turn the selector knob to the RECOVER position. Mode 1 Recovery Only, cont. Control Panel Features WEIGHT TIME (MIN) PURGE MODE STATUS LINE 2LB 4OZ 15MIN N 3 CHARGING 6 Initial Setup To ensure quick, successful integration of the 37880 into your shop, please follow these set-up procedures before the first use of the unit. To access the information, press Mode 7, REFRIGERANT MANAGEMENT SYSTEM. Leak detectors have date of manufacture label on product. All returns must be PREPAID. When the filter drier reaches 100 lbs of refrigerant processed it will warn the user that it is nearing the end of its life. RECOVERING CONTAMINATED REFRIGERANT WILL VOID ALL WARRANTIES AND MY CAUSE DAMAGE TO OTHER AUTOMOBILES THAT YOU SERVICE IN THE FUTURE. The unit is now ready for operation. All refrigerant containers, equipment, and hoses are under pressure. If the filter begins to turn red in color stop using the re- frigerant identifier immediately. 2. Verify the message on the LCD reads RECOVERY COMPLETE. 7. Use only new lubricant to replace the amount removed during the recycling process. Heavy-duty shock resistant scale for accurate charging. On direct drive pumps, many of the problems can be solved over the telephone. The LCD shows error codes for rapid di- agnosis of abnormal conditions. Trays for pens, small parts, tools and other misc. Remove the tank refill adapter from empty R-134a virgin cylinder and place it in the tool tray located on top of the unit. MODE 5 - Oil inject, injects the oil into the system. Step 2: FILL SOURCE TANK WITH REFRIGERANT (also see page 11) 1. Status Line - Displays programming commands and informs the user of current status of the unit. No authorization is required. Press the RESET key to return to SELECT MODE. 4. Weight - Shows the weight of refrigerant being processed in each mode. WARNING: DO NOT RECOVER CONTAMINATED REFRIGERANT WITH THIS UNIT. 3. Rotate the front of the vacuum pump out to expose the oil fill port. This mode will then proceed to recharge the A/C system. 2. Connect the blue low side auto service hose to the new refrigerant source tank and open the tank valve. Shop Electronics & Diagnostics with everyday low prices and fast shipping. Contaminated refrigerant is to be recovered with an approved contaminated recovery device (P/N 37825) before service can be performed. 4. 2. If the refrigerant does not pass the identification proc- ess (98% purity) the unit will display the error message CONTAMINATED and the screen will show the re- sults of the identification. Refer to the Pre-Operation Check List. Check the pressure in the tank to determine if the system is purging unnecessarily. NOTE: If desired, the gauges of the 880 SERIES can now be used to aid investigation of an A/C sys- tem problem. Plug the unit into a 100-240VAC grounded power source. One key, the Refrigerant Management System Key, is located on the right side. Responda perguntas de provas passadas e avalie sua preparao. JB Tools provides this disclaimer to ensure there is no likelihood of confusion unduly influencing your decision to purchase this product, or any other, product from JB Tools, and to ensure there is no confusion as to the existence of any affiliation between JB Tools and the manufacturer of this product. An E will display on the LCD if the previous purge was insufficient to lower the non-condensable gas value below the limit. Charge accuracy within 1/2 oz. 6. Logging and storage of jobs for future reference and refrigerant usage. Press RMM key to cycle through the screens. 4. One year parts and labor warranty (see warranty statement for exclusions). Maintenance reminders for oil/filter changes. The unit will shut off automatically when either the supply tank is empty or the storage tank is full. An E indicates the unit purged for thirty (30) seconds and non- condensable gases are still present. Failure to follow these procedures could void all warranties. Release the key when the correct amount of oil has been added to the system. Charge only capability for R-134a (not permitted for R-1234yf per standards). This mode is most often used prior to opening an A/C system to atmosphere to replace a system component. Automatic shut-off for full tank and high pressure situations. Hose, Yellow Jacket 37837 R-134A Hybrid Refrigerant Management System with Printer, Yellow Jacket 37841 Refrigerant Management System Automatic for R-134a, Yellow Jacket 37885 Heavy Duty, Basic 10' hoses and 3 CFM Vacuum Pump, Yellow Jacket 68961 Refrigerant Analyzer for R-134a and 1234yf, Yellow Jacket 37825 Contaminated Refrigerant Recovery Machine, CPS Products FA1000 Deluxe R134a Recovery/Recycle & Recharge w/8' Hoses & 50 lb. For all other products, please return warranty items to the main factory in Bloomington, MN, prepaid for credit, replacement, or repair, at our option.
The new J2788 standard requires that the unit lock out if the filter drier is not replaced at the proper interval. 12 Purging Non-Condensable Gases The 37880 is designed to automatically purge non- condesable gases such as air present in the storage tank.
5. Always inspect hoses, o-rings, and fittings for damage be- fore using equipment. Simple operation for oil waste and airpurge, Micro processor controlled recharge makes the AR2700 accurate to 1/10 oz or 4grams, Easy to read high and low pressuregauges, High efficiency 6 CFM vacuum pump will dehydrate the system to 50microns. LIT, YELLOW JACKET Electric/Manual Lightweight Flaring Tool Instructions Flaring Instructions Step 1: Use a reamer to clean the tube.. 9. Press the ENTER key. Step 1: FILL VACUUM PUMP WITH OIL 1. 6. Refrigerant measurement during charging is extremely accurate. The purge time is set to 30 seconds to minimize refrigerant loss. Replace the refrigerant identifier filter and continue using the refrigerant identi- fier. 239-529-0011. Manual de operao de estao de recuperao de sistema de ar condicionado. 5. Tire suas dvidas lendo as respostas dadas por outros alunos como voc. The unit will purge the next time it is turned off and on. 10 Models with the optional refrigerant identifier 37881 The unit will display IDENTIFY REFRIG ? To make your selection use the increase and decrease keys to toggle from Y to N. Press the Enter key to make your selection and then press the Start key to start the process. Yellow Jacket 37840 Refrigerant Management System Automatic for R-134a with 10? You must understand the proce- dures outlined in this manual. SAE J2843 for R-1234yf requires 98%+ purity for vehicle refrigerant in order to service the vehicle with any RR&R equipment. FUNCTION C - WEIGHT CONVERSION. Refer to Pre-Operation Check List. Not ready for R-1234yf? Minimum restocking charge 20% on standard items of current date coding and manufacture. MODE 2 Operational Steps 1. All refrigerant must be removed from the old filters before they are removed. Your email address will not be published. Follow this procedure to add refrigerant to the storage tank. Moisture in an A/C system can cause erratic operation and must be removed be- fore recharging the system with refrigerant. Open the service hose valves. FUNCTION B - DECREASE. By purchasing this product from JB Tools, purchasers may not be guaranteed any manufacturer-provided services offered by the manufacturer of this product (including any training or technical support that may otherwise be available). Bypass vacuum time by setting time to zero (FULL CYCLE MODE only). Dispose of recovered oil in a proper manner. Attach the tank refill adapter (Part No. Refer to the Pre-Operation Check List. LP SWITCH OPENED DURRING VAC- UUM HOLD REPEAT VACUUM CYCLE ERROR 14 LEAK CHECK FAILD FAILED TO HOLD VACUUM AFTER 5 ATTEMPTS REPEAT RECOVERY PROCESS CHECK FOR LEAKS ERROR 15 SYSTEM MAL- EEP-ROM Data read/write error REPLACE MICROPROCESSOR 16 37880 Repair Parts List Part # Description 95423 High Pressure Switch 95180 Vacuum Switch W/COMP Capacitor W/COMP Relay 38026 Differential Switch 38111 Membrane Touch Pad Microprocessor 95157 Circuit Breaker, 15 Amp 68826 Automatic Scale Assembly Part # Description 27296 R-134a Auto Low Side Blue Hose (10ft) 27696 R-134a Auto High Side Red Hose (10ft) 00849 R-134a Tank Vapor Blue Hose (30in) 00853 R-134a Tank Liquid Red Hose (30in) 19153 R-134a Tank Refill Adapter 95006 50lb Refrigerant Tank 38003 Filter-Dryer (1 per unit) 38019 Oil Bottle 38053 Service Compressor Ritchie Engineering Co., Inc. Recovery Division 6701 W. 110th St. Bloomington, MN 55438 USA Phone: 952-943-1333 Toll Free: 800-769-8370 Fax: 952-943-1605 Toll Free: 800-322-8684 E-mail: custserv@yellowjacket.com Web Site: www.yellowjacket.com Warranty Information LIMITED WARRANTY Ritchie Engineering guarantees YELLOW JACKET products to be free of defective material and workmanship which would affect the life of the product under normal use for the purpose for which it was designed. 3. 2.
Shop Specialty Tools with everyday low prices and fast shipping. Tablet follows manufacturers warranty. See recommended hose safety inspection procedure. Failure to replace the filter will cause damage to the refrigerant identifier and void all warranties related to the refrigerant identifier. Mode 5 Oil Inject When prompted, press this key and watch the oil inject bottle until the correct amount of oil has been injected. Press WEIGHT CONVERSION to change the displayed units of weight. The filters must be changed periodically to ensure the system is working properly.
50 pound storage tank (3784x) and 30 pound storage tank (3786x). Pesquise entre todos os recursos de estudo, Estude com provas passadas, TCCs e dicas teis. Models with the optional refrigerant identifier 37881 The unit will display IDENTIFY REFRIG ? To make your selection use the increase and decrease keys to toggle from Y to N. Press the Enter key to make your selection and then press the Start key to start the proc- ess.
Operation Keys START- Press START to begin a selected operational mode. items. All prices are in USD 2022 JB Tools Inc. Genius Ecommerce by 1Digital. The free downloadable app wirelessly calculates and displays the A/C systems actual pressures in an easy-to-read color format on the RMS tablet, as well as iOS or Android devices. After the system turns off, the unit will beep to alert the technician the job is complete. Manufacturers occasionally suggest that products be advertised at their suggested retail price. The filter driers are marked with a unique code that will be required to unlock the unit. The screens contain the following information: Screen 1: Last Job Information Run Time Refrigerant Recovered Refrigerant Charged Refrigerant Added Screen 2: Year-to-date Information Total Run Time Total Amount Recovered Total Amount Charged Refrigerant Added New WARNING: DO NOT RECOVER CONTAMINATED REFRIGERANT WITH THIS UNIT. Optional side bag with eight (8) pockets holds full sized notepad, two beverages, cell phone and more. However, JB Tools customers can rest assured that JB Tools stands behind its Warranty Program and its Manufacturer Matching Policy,100% of the time. Avoid cross-contamination of refrigerant. Special production items will have a higher restocking charge. Repeat the identification process to insure the proper identification of the refrigerant purity level. 1. 3. Estude fcil! The RESET may have to be pushed more than once to return to Select Mode screen. If this occurs take the appropriate steps to locate the leak and properly repair it. NON-WARRANTY RETURNS - Prior authorization must be obtained from home office for non-warranty returns. Uses of the refrigerant data include: Improved record keeping Accurate determination of net profits Reduced billing errors Minimized refrigerant loss from leaks and theft Reduced operator errors The refrigerant management information is stored in eight registers. Plug unit into a grounded 110V outlet. JB Tools commitment to 100% customer satisfaction is unparalleled, which is why JB Tools offers its customers a best-in-class Warranty Program to all of its customers on all products sold by JB Tools. Built for the workingman. Comes with a 50Lbs tank included with the purchase of an AR2700, 115 Volts, 50/60 HZ, Single phase, PSI/KPa gauges. When the unit stops, turn the selector knob to CLOSE, secure the system and unplug the machine. RESET- Press RESET to cancel the current opera- tion. If the refrigerant does not pass the identification proc- ess (98% purity) the unit will display the error message CONTAMINATED and the screen will show the results of the identification. Replace the refrigerant identifier filter and continue using the refrigerant identi- fier. Using a funnel, insert oil to the oil level line using the provided YELLOW JACKET vacuum pump oil. During the recovery operation, refrigerant is removed from both the high and low side of the automobile air condition- ing system. Release the button and press EN- TER to accept the vacuum hold time shown on the LCD. Shop Battery & Charging Systems with everyday low prices and fast shipping. Purchase the 37840 for R-134a today and we can update it to R-1234yf later with our optional (one time use) conversion kit. Press the RESET button. Utilizes manual ball valves in place of solenoids making the AR2700 impervious to contamination andsealants. If the unit fails the second time follow the on screen in- structions and take the appropriate steps to remove the contaminated refrigerant with a separate unit for re- moval of contaminated refrigerant. Press the RESET key to return to the SELECT MODE status. Make certain all safety devices are functioning properly before operating equipment. 5 Mode keys are located on the left side of the control panel. Turn on the main power switch. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OF QUALITY, WHETHER WRITTEN, ORAL OR IMPLIED. The easy-to-use, portable, full color interface walks you quickly through each step for easy operation and fast service. If the unit continues to display Y or an E and the tank pressure is near the value in the table below, contact Ritchie Engineering Customer Service at (800)769-8370. This mode also allows the tech- nician to verify the A/C system will hold a vacuum for a certain length of time. Shop Paint, Body & Exterior with everyday low prices and fast shipping. When the LCD reads SET VACUUM HOLD TIME, set the vacuum hold time by pressing and holding INCREASE or DECREASE until the desired time is shown. 1. MODE 1 Operational Steps 1. 7. Shop Apparel with everyday low prices and fast shipping.
Meets standard requirements for vacuum pull control and system leak test. Maintenance Reminders Approximate Pressure (psig) Temp (F) R-12 R-134a 65 74 74 70 80 81 75 87 88 80 96 97 85 102 115 Temp (F) R-12 R-134a 90 110 120 95 118 126 100 127 135 105 136 145 110 146 155 FILTER - MAINT-FILTER CHG DUE The 37880 has a unique filter system which ensures the refrigerant transferred to the storage cylinder is clean and moisture-free. Choose from high- or low-side charging for vehicles with only one service fitting. Mode 1 Recovery Only 7 6. Correction in the manner provided above shall constitute a fulfillment of all liabilities with respect to the quality, material and workman- ship of the product. Holding the button depressed will increase the rate of change. Discard used lubricant per applicable federal, state and local requirements. Turn the selector knob to the RECOVER position. Mode 1 Recovery Only, cont. Control Panel Features WEIGHT TIME (MIN) PURGE MODE STATUS LINE 2LB 4OZ 15MIN N 3 CHARGING 6 Initial Setup To ensure quick, successful integration of the 37880 into your shop, please follow these set-up procedures before the first use of the unit. To access the information, press Mode 7, REFRIGERANT MANAGEMENT SYSTEM. Leak detectors have date of manufacture label on product. All returns must be PREPAID. When the filter drier reaches 100 lbs of refrigerant processed it will warn the user that it is nearing the end of its life. RECOVERING CONTAMINATED REFRIGERANT WILL VOID ALL WARRANTIES AND MY CAUSE DAMAGE TO OTHER AUTOMOBILES THAT YOU SERVICE IN THE FUTURE. The unit is now ready for operation. All refrigerant containers, equipment, and hoses are under pressure. If the filter begins to turn red in color stop using the re- frigerant identifier immediately. 2. Verify the message on the LCD reads RECOVERY COMPLETE. 7. Use only new lubricant to replace the amount removed during the recycling process. Heavy-duty shock resistant scale for accurate charging. On direct drive pumps, many of the problems can be solved over the telephone. The LCD shows error codes for rapid di- agnosis of abnormal conditions. Trays for pens, small parts, tools and other misc. Remove the tank refill adapter from empty R-134a virgin cylinder and place it in the tool tray located on top of the unit. MODE 5 - Oil inject, injects the oil into the system. Step 2: FILL SOURCE TANK WITH REFRIGERANT (also see page 11) 1. Status Line - Displays programming commands and informs the user of current status of the unit. No authorization is required. Press the RESET key to return to SELECT MODE. 4. Weight - Shows the weight of refrigerant being processed in each mode. WARNING: DO NOT RECOVER CONTAMINATED REFRIGERANT WITH THIS UNIT. 3. Rotate the front of the vacuum pump out to expose the oil fill port. This mode will then proceed to recharge the A/C system. 2. Connect the blue low side auto service hose to the new refrigerant source tank and open the tank valve. Shop Electronics & Diagnostics with everyday low prices and fast shipping. Contaminated refrigerant is to be recovered with an approved contaminated recovery device (P/N 37825) before service can be performed. 4. 2. If the refrigerant does not pass the identification proc- ess (98% purity) the unit will display the error message CONTAMINATED and the screen will show the re- sults of the identification. Refer to the Pre-Operation Check List. Check the pressure in the tank to determine if the system is purging unnecessarily. NOTE: If desired, the gauges of the 880 SERIES can now be used to aid investigation of an A/C sys- tem problem. Plug the unit into a 100-240VAC grounded power source. One key, the Refrigerant Management System Key, is located on the right side. Responda perguntas de provas passadas e avalie sua preparao. JB Tools provides this disclaimer to ensure there is no likelihood of confusion unduly influencing your decision to purchase this product, or any other, product from JB Tools, and to ensure there is no confusion as to the existence of any affiliation between JB Tools and the manufacturer of this product. An E will display on the LCD if the previous purge was insufficient to lower the non-condensable gas value below the limit. Charge accuracy within 1/2 oz. 6. Logging and storage of jobs for future reference and refrigerant usage. Press RMM key to cycle through the screens. 4. One year parts and labor warranty (see warranty statement for exclusions). Maintenance reminders for oil/filter changes. The unit will shut off automatically when either the supply tank is empty or the storage tank is full. An E indicates the unit purged for thirty (30) seconds and non- condensable gases are still present. Failure to follow these procedures could void all warranties. Release the key when the correct amount of oil has been added to the system. Charge only capability for R-134a (not permitted for R-1234yf per standards). This mode is most often used prior to opening an A/C system to atmosphere to replace a system component. Automatic shut-off for full tank and high pressure situations. Hose, Yellow Jacket 37837 R-134A Hybrid Refrigerant Management System with Printer, Yellow Jacket 37841 Refrigerant Management System Automatic for R-134a, Yellow Jacket 37885 Heavy Duty, Basic 10' hoses and 3 CFM Vacuum Pump, Yellow Jacket 68961 Refrigerant Analyzer for R-134a and 1234yf, Yellow Jacket 37825 Contaminated Refrigerant Recovery Machine, CPS Products FA1000 Deluxe R134a Recovery/Recycle & Recharge w/8' Hoses & 50 lb. For all other products, please return warranty items to the main factory in Bloomington, MN, prepaid for credit, replacement, or repair, at our option.